High Voltage Capacitor

Sharda is producing power compensation capacitors since 20 years

Read More

Surge Absorbing / Protective Capacitor

surge protection capacitors are of special type capacitors. Its application is of specialized nature i.e. in case of abnormal condition.

Read More

Low Voltage Panel Mounted APP Capacitor

Low Voltage i.e. up to 650volt, are from 5KVAr to 50KVAr in single units and for further range in banking system as per customer requirement

Read More

High & Low Voltage Capacitor Panel

For optimum utilization of available power the reactive power consumption should be reduced or nullified i.e. power factor should be unity

Read More

Metalised Poly Propolin Capacitor

To overcome this problem the new technique is employed i.e. To use Metallized Polypropylene Film instead of AllPolypropylene Film

Read More

Condenser

We Manufacturers Condenser, Running Condenser, Starting Condenser

Read More

Automatic Power Factor Controller Panels ( APFC Panel )

 

For optimum utilization of available power the reactive power consumption should be reduced or nullified i.e. power factor should be unity, hence, most of the Power Distribution companies have policy to penalize the industrial and commercial consumers for not maintaining power factor above certain limit (generally above 0.90 value). However, due to reactive power drawn by capacitive or inductive load in the consumer premises the power factor is either lagging or leading, thus to maintain it within limit i.e. for compensating or supplying required KVAR, the capacitors (in case of lagging PF) or reactors ( in case of leading PF) are connected across the system. For stable load the fixed KVAR compensation is required , while for variable load the KVAR requirement also changes as per the load duration cycle, thus in such case the Automatic Power Factor control Panel is installed

Electric Power quality is a term that has captured increasing attention in power engineering in the fresh years. The power quality is mainly depends on the needs of the equipment that is being supplied. Usually the term it refers for maintaining a sinusoidal waveform of bus voltages at rated voltage and frequency. The waveform of electric power at generation stage is purely sinusoidal and free from any distortion. All the Power conversion and ingesting equipment are also designed to function under pure sinusoidal voltage waveforms. However, lots of devices that distorted the supply waveform. These distortions may spread all over the electrical network. In fresh years, there has been an increased use of non-linear loads, which has resulted in an increased fraction of non-sinusoidal currents and voltages in Electric Network. Classification of power quality areas may be made according to the source of the problem such as converters, magnetic circuit non linearity, arc furnace or by the wave shape of the signal such as harmonics, flicker or by the radio frequency interference.

 
High and Low Voltage Capacitor Panel
HT &LOW VOLTAGE Capacitor Panel
 
 
Application :  
For Improving Lagging Power Factor of peak loads Systems
 
Specification :
• Multistage controller
• Auto/manual controller
• P.F. Closer to unity/Targeted
• Thyristor/Contractor Switched
• Zero voltage switching as per controller
• Suitable for variable load.